EKE-Trainnet
ANALOGUE INPUT/OUTPUT MODULE (AIO)

Four 4...20 mA analogue inputs grouped in two groups
Two 4...20 mA analogue outputs
I/O connections either at rear or at front
Input and output channel filtering
Self-diagnostics
I/O state and module status indicators SDLC type serial bus interface
The AIO module is an intelligent analogue
I/O interface module that can be located
in the Coach Computer or distributed
within the coach. The module has its own
8-bit embedded processor and a Vehicle
Bus interface.
The module’s 4 analogue input channels
are separated into two groups, and the
optional output channels form a third
group. Each group provides its own voltage
and return signals for external I/O
circuits.
The module’s embedded microprocessor
controls the inputs and outputs. Each input
channel has parameters for calibration
(factory set). For the Coach Computer
the module has an SDLC-type Vehicle
Bus interface.

Properties and Interfaces
Analogue inputs.
The type of the analogue inputs is current loop (4...20 mA).The inputs do not need to be calibrated by the user, as all channels are factorycalibrated.The resolution of the input A/D conversion is 12 bits, and the cut-off frequency of the hard-ware low pass filter is 100 Hz. The board’s software runs average type filtering, the typical length of which is 16 samples at a sample rate of 40 ms, thus providing a cut-off frequency of approximately 1 Hz.
Analogue outputs. The type of the analogue outputs is current loop (4...20mA).
The resolution of the output A/D conversion is 12 bits.
Self diagnostics. The module has normal power-on self-tests for memories.
I/O indicators. The AIO module has LED bar indicators for input and output channel levels.
I/O connections. The module has two configurations, one configuration for I/O connections at rear and the other for I/O connections at front. Both configurations have a similar I/O functionality, but the front configuration doesn’t have the module status indicator or I/O indicator LEDs.
The EKE-Trainnet® AIO module
EKE-Trainnet® AIO module block diagram
EKE-Trainnet® is a registered trademark of EKE-Electronics Ltd.
All data subject to change without notice.
Technical Information:
DIMENSIONS:
4 TE × 3 U × 160 mm (W × H × D), weight 160 gINPUT POWER: 5 VDC ± 5% (1000 mA max., 250 mA typ.)
MTBF: 400 000h (25°C)
TEMPERATURE RANGE: Operational -40°C … +70°C
I/O CONNECTOR: DIN41612-D (at rear) or DIN41612-F (at front)
I/O BUS: RS485, SDLC/Modbus 375 kbps
TEST INTERFACE: RS232C, asynchronous 19.200 bps
INPUT AND OUTPUT CHANNELS
Input type: Current loop input (4 ... 20 mA)
Input loop supply voltage: 8...36 VDC
Input accuracy: ± 0.5% of full scale (12 bit)
Cut-off frequency: 1 Hz (software sampling)
OUTPUT CHANNELS (OPTIONAL)
Output type: Current loop input (4 ... 20 mA)
Output loop supply voltage: 8...36 VDC
Output accuracy: ± 0.5% of full scale (12 bit)
Refresh rate: 40 ms